News
Your location:home>>cam and groove coupling>>news>>detail

Last:The transmission fluid of hydraulic cam and groove coupling Next:The safety device not spraying liquid of hydraulic cam and groove coupling--Mechanical thermostat switch

Electronic temperature control switch of hydraulic cam and groove coupling

Source: Notetime: 2013-12-10 11:05:52 click: 2612

  Another safety protection device of hydraulic cam and groove coupling not spraying liquid: electronic temperature control switch.

  Its structure and principle are to install a magnetoelectric sensor probe in the coupling shell is fixed on the bracket, the magnetoelectric sensor, coupling overload after reducing speed, when reaching the set speed ratio, speed monitoring on alarm and stop instruction, thereby protecting the overload.

  Advantages of the electronic temperature control switch of hydraulic cam and groove coupling is guaranteed without liquid injection, provide reliable overload shutdown safety protection.

  When in the operation, it can be selected according to the requirement of safety protection speed.

  The disadvantage is that the structure is more complex, price is high.

  In order to prevent the electronic component failure, still need to install the spray type fusible plug for final protection of hydraulic cam and groove coupling.

  Note:

  A. still need to install the ordinary fusible plug for final protection;

from:http://www.bauercoupling.com/newsd-nid-92.html